LNG facility siting: The benefits of using advanced modelling tools in your study

 

Imagine a bustling port city where a new Liquefied Natural Gas (LNG) facility is being planned in the industrial zone. The project promises economic growth and job opportunities, attracting investment and benefiting local residents. However, LNG facilities come with significant risks that cannot be ignored. A single incident could have catastrophic consequences, not only for the facility but for the entire community.

Given the potential hazards associated with LNG facilities, including explosion risks and toxic releases, careful planning is essential. This is where advanced modelling tools come into play, offering a way to predict and mitigate potential risks. In this article, we’ll explore how these tools contribute to the safe and effective siting of LNG facilities.

The growing importance of LNG in a decarbonising world

Before we dive into the specifics of LNG incidents, it’s essential to understand the nature of the substance we’re dealing with. LNG is methane that has been cooled to -162°C (-260°F), condensing it into a liquid form. This process reduces its volume by about 600 times, making it easier and more economical to transport over long distances. 

LNG is recognised as the cleanest fossil fuel, producing significantly lower pollutants and emissions compared to other fossil fuels. This positions LNG as a key alternative energy source in global efforts to reduce greenhouse gas emissions and the transition towards net zero targets.

LNG’s versatility extends across various applications, including heating homes, fuelling industrial boilers, and generating electricity. Its ease of transport and high energy density make it particularly suitable for use in remote areas. The LNG value chain encompasses several stages: gas extraction, processing, storage, liquefaction, transportation, regasification, and distribution to the end user.

LNG value chain involves gas extraction, processing, storage, liquefaction, transportation, regasification, and distribution to the end user.
Figure 1. LNG value chain.1

Global demand for LNG is expected to increase over the next 20 years, reflecting its increasing role in the energy landscape.2 This growth is partly driven by its integration into decarbonisation strategies in countries such as China, where coal remains a dominant energy source. Additionally, the shipping industry has seen a rise in LNG use, with larger vessels, including container ships and cruise ships, adopting LNG over traditional marine fuels that tend to produce higher emissions.

Despite its benefits, the processes associated with LNG operations, including liquefaction, storage and distribution, present several safety challenges.

A key aspect of managing risks associated with LNG facilities is determining their safest location and layout. This is where facility siting studies become critical to ensure these sites are safe and risks are properly controlled.

Watch a webinar to learn more about hazards at LNG facilities.

Learn more

Facility siting and its role in LNG safety

Facility siting for an LNG facility assesses the risk of exposing occupied buildings, both within or around the facility, to the hazards posed by the facility.

The primary goal of facility siting is to select suitable locations and optimise the layout to ensure the safety of both the site boundary and nearby occupied buildings. This process should be continuous throughout the facility’s life and can be approached in several ways:

Ensuring the safety of occupied buildings is a key aspect of facility siting studies. These studies also address emergency response planning, evacuation routes, and environmental protection measures, which are all critical for LNG safety.

In the United States, facility siting is mandated as part of the OSHA (Occupational Health & Safety Administration) Process Safety Management (PSM) Regulation. Facility siting studies are essential to comply with these regulations and to protect people and property from the hazards associated with LNG operations.

In the UK and Europe, major hazard sites are subject to broader regulatory requirements. Unlike the specific ‘facility siting’ requirements in the US, European regulations, such as the Seveso III Directive, focus on preventing and mitigating the consequences of major accidents through land use planning.

These regulations, supported by safety reports and risk assessments like Quantitative Risk Assessments (QRAs) or Occupied Building Risk Assessments (OBRAs), help ensure that LNG facilities are safely located and designed in relation to their surroundings.

The European standard EN 1473 demands the performance of a hazard assessment, which can be either deterministic or probabilistic. Modelling of hazardous events can provide the detailed and reliable inputs needed for these assessments. Both NFPA 59A and the European standard EN 1473 both recognise the importance of QRAs in supporting effective facility siting.

Examples of regulations and standards for LNG facility siting

Various regulations and standards govern the siting and layout design of LNG facilities to ensure safety and compliance.

In the United States, several key regulations and standards apply:

  • PHMSA regulations, 49 CFR 193:
    • These set safety standards for the siting, design, installation, and construction of LNG facilities involved in gas transportation by pipeline.
  • NFPA 59A:
    • This standard outlines requirements for the production, storage, and handling of LNG, with specific guidelines for the location and design of LNG plants.
  • API Recommended Practice 752:
    • Provides guidance on managing risks to personnel in occupied buildings from potential hazards such as explosions, fires, and toxic releases.
  • API Recommended Practice 753:
    • Provides guidance on reducing risks to personnel located in portable buildings from potential explosion, fire and toxic release hazards (American Petroleum Institute, n.d.)

In Europe and other regions, different directives and standards are in place:

  • EN 1473:
    • Offers guidelines for the design, construction, and operation of onshore LNG installations.
  • Seveso III Directive:
    • Focuses on preventing and mitigating the consequences of major industrial accidents.
  • ISO 16924:
    • Provides standards for the design, construction, operation, maintenance and inspection of LNG fuelling stations and on-site sources.

Challenges in LNG facility siting studies

LNG facility siting studies present several challenges. One of the key difficulties lies in accurately predicting the impact of incidents such as vapour cloud explosions, fires, or toxic releases. These events can have devastating consequences for both the facility and surrounding areas.

The challenge is compounded by the need to account for a range of variables, including weather conditions, topography, the presence of obstacles, and the proximity of populated areas. Without precise tools, it can be difficult to assess how these factors influence the spread and impact of hazardous events, presenting a risk of either overdesigning or underdesigning safety measures. Overdesigning can lead to unnecessary costs and inefficiencies, while underdesigning can result in inadequate protection against potential hazards.

Another significant challenge is balancing safety requirements with operational and economic considerations. LNG facilities often need to be located near existing infrastructure, such as pipelines and transportation hubs, which increases the risk of exposure to potential hazards. Additionally, regulatory requirements may impose strict safety guidelines, but these must be weighed against the practicalities of land use and cost efficiency.

To tackle these challenges, advanced modelling tools provide valuable support by offering detailed simulations of potential incidents. These tools allow engineers to explore various scenarios and optimise facility siting and layout, ensuring both safety and operational viability.

Incorporating modelling into the siting process

Modelling tools can be used to reliably simulate the consequences of loss of containment scenarios and assess the risks associated with LNG facility hazards, ultimately helping to achieve a safer plant design.

Some may wonder why modelling is required, given that prescriptive separation between pieces of equipment, safety distances to the site boundary, and exclusion zones around the facility can be found in guidance documents. However, these may not accurately reflect every facility. For circumstances where process conditions are not typical or where the surrounding geometry may significantly affect the outcome of an event, then modelling should be conducted.

In a consequence-based approach, modelling can be used to assess several key aspects:

  • The fire rating or blast resistance required for a building in a particular location.
  • Exclusion zones and zone boundaries.
  • Suitable building or equipment locations based on an already decided fire rating, blast resistance or maximum threshold criteria.
  • Separation distances between equipment or process units to prevent an escalation of events.
  • The effectiveness and location of mitigation measures, such as barriers.
  • The site layout with respect to consequences at the boundary.

For a risk-based approach, modelling serves to:

  • Assess both the likelihood and consequences of events to establish acceptable risk thresholds.
  • Prioritise safety measures based on the probability and severity of potential incidents.
  • Compare different facility designs or layouts to identify the option with the lowest overall risk.
  • Demonstrate that deviations from prescriptive standards still maintain risks within acceptable limits.
  • Support cost-benefit analysis by balancing the frequency of events against potential consequences to ensure efficient safety investments.

Incorporating modelling into a risk-based approach to facility siting allows for the determination of individual, societal, or consequence-based risk levels where consequence risk refers to the probability of exceeding a physical threshold. This enables engineers to assess whether the current design meets the company and relevant authority’s tolerable risk criteria or to determine the most suitable layout and location based on the calculated risk contours.

To illustrate how this works in practice, let’s look at a specific example where modelling tools played a crucial role in the safe and efficient siting of an LNG facility.

An example of how advanced modelling supports LNG siting process

Siting LNG facilities requires careful planning and risk assessment to ensure the safety of both the facility and its surroundings. A clear example of how advanced modelling can assist in this process is seen in Gexcon’s work on the UK’s first multifunctional LNG terminal.

The LNG terminal is designed to handle various operations, including storage, regasification, and distribution. The key challenge was to develop a safety strategy that accounted for different operational scenarios, potential hazards, and the unique conditions of the site, which was situated on uneven terrain.

A 3D geometrical model of the LNG facility to be implemented within FLACS for LNG facility siting
Figure 2. A 3D geometrical model of the LNG facility to be used in FLACS, an advanced CFD modelling tool.

To meet these challenges, advanced modelling tools were used. Simulations of potential incidents, such as gas dispersion, fires, and explosions, provided valuable insights into the risks associated with different scenarios, helping to inform the siting and design of the facility.

For example, modelling assessed the potential impact of a vapour cloud explosion, taking into account the site’s specific layout and environmental conditions. This allowed the project team to determine the best placement of critical infrastructure, ensuring key areas were protected.

When demonstrating the safety of the facility layout to stakeholders and regulatory authorities, contour plots were used to clearly communicate the results of these simulations. Such visual tools have been effective in conveying complex information and gaining approval from regulatory bodies.

Read the complete case study.

Learn more

This example demonstrates the value of advanced modelling tools in ensuring the safe and optimal design of LNG facilities. By accurately predicting the consequences of potential hazards and using these insights to optimise plant layout, these tools play a crucial role in effective facility siting.

As we move forward, a range of advanced consequence and risk modelling tools are available to tailor analyses to the specific needs of each LNG siting project. Let’s explore some of the available options.

Advanced modelling tools for LNG siting studies

Safety engineers and consultants have access to a variety of advanced consequence and risk modelling tools for LNG siting studies, each offering different levels of complexity and detail to suit the specific needs of a project. Among the leading tools in the industry are FLACS and EFFECTS for consequence modelling, and RISKCURVES for risk modelling, all developed by Gexcon, experts in LNG safety. These tools are widely recognised for their accuracy and effectiveness, enabling professionals to conduct detailed analyses and make well-informed decisions.

FLACS

FLACS CFD modelling software has been extensively validated against real-world experiments for LNG fire, dispersion, and explosion scenarios, including against the entire database from the Model Evaluation Protocol for LNG Vapor Dispersion Models (the LNG MEP). It is the only CFD model approved for LNG vapour dispersion by the US Department of Transportation (DOT) for 49 CFR 193.3

Video 1. Modelling LNG dispersion using FLACS.

Terrain, complex geometries, obstructions (including sumps or trenches) and environmental conditions can be captured in FLACS to produce a realistic simulation of the accident scenarios. This means that FLACS can effectively simulate a range of loss of containment scenarios, including:

  • Pool spills on water or land, subsequent pool spread, and dispersion
  • Pressurised, flashing jet releases and subsequent gas dispersion
  • Fire events following ignition of a pool or jet release
  • Explosion events resulting from the delayed ignition of a release
Video 2. Modelling a Vapour Cloud Explosion (VCE) using FLACS.

Advanced CFD tools like FLACS are particularly valuable in LNG siting studies for modelling scenarios where:

  • A detailed view of the resulting contours is required
  • The local geometry is complex, and/or there is significant local congestion
  • The effects of terrain across or surrounding the facility need to be considered
  • Shielding effects are not insignificant, for example, if barriers are positioned around occupied buildings
Jet fire modelling study with FLACS to assess a range of scenarios and determine the design and location of additional risk reduction measures for LNG facility siting
Figure 3. Modelling a jet fire using FLACS

EFFECTS and RISKCURVES

EFFECTS and RISKCURVES are also well-equipped to model LNG-related scenarios, with internal models for pool evaporation, pool fire, and heavy gas dispersion that have been validated against experiments to ensure trustworthy and realistic results. These tools are particularly useful for preliminary evaluation and less complex geometries, as they are typically less time-consuming and costly than detailed CFD studies.

EFFECTS is an advanced integral consequence modelling tool that aids in optimising facility layout and siting. It provides a preliminary analysis of potential hazards, and their consequences, and helps stakeholders understand the implications of various design choices. EFFECTS allows for the quick calculation of distances to particular consequence thresholds, which is potentially required by authorities involved in land use planning.

Modelling a polygonal-shaped pool fire in EFFECTS consequence analysis software
Figure 4. Modelling a polygonal-shaped pool fire in EFFECTS.

RISKCURVES, a risk modelling software tool, is designed to perform QRA studies, as recommended by both NFPA 59A and EN 1473 for LNG facility siting. Detailed risk assessments conducted using RISKCURVES can support land use planning and inform zoning decisions based on risk levels and consultation distances.

Performing risk analysis for an LNG port using RISKCURVES QRA software
Figure 5. Performing risk analysis for an LNG port using RISKCURVES.

The examples from FLACS, EFFECTS, and RISKCURVES show how these modelling tools help in assessing risks and guiding the siting and design of LNG facilities. By offering insights into potential hazards and supporting risk management, these tools are key to making informed decisions.

Next, let’s explore the benefits these tools provide in LNG siting studies.

Benefits of using consequence and risk modelling tools in LNG siting studies

The siting of LNG facilities involves complex decisions that must balance safety, regulatory compliance, operational efficiency, and cost. Advanced consequence modelling tools like FLACS and EFFECTS, along with risk modelling tools such as RISKCURVES, offer significant benefits in navigating these challenges, ensuring that facilities are designed and located to minimise risk and maximise safety.

  • Enhanced accuracy and reliability

One of the main benefits of tools like FLACS and EFFECTS is their ability to deliver accurate and realistic simulations of hazardous scenarios. For instance, FLACS can accurately model LNG fires, vapour cloud explosions, and gas dispersion, considering complex geometries, terrain, and environmental conditions. This enables safety engineers to predict how incidents might unfold at a facility, leading to better-informed decisions about site layout and design.

  • Cost and time efficiency

While detailed CFD studies using tools like FLACS provide deep insights, they can be time-consuming and resource-intensive. Tools like EFFECTS and RISKCURVES offer a more cost-effective and quicker alternative for preliminary evaluations and less complex scenarios. These tools enable safety professionals to quickly assess potential hazards, calculate safe distances, and identify key risks without the need for extensive computational resources. This efficiency is particularly valuable in the early stages of a project, where quick, reliable assessments are necessary to guide further planning.

  • Comprehensive risk assessment

RISKCURVES complements consequence modelling by allowing for detailed QRAs. This tool integrates the likelihood of hazardous events with their potential impacts, providing a comprehensive view of the risks associated with different facility designs and locations. By incorporating both consequence and risk-based approaches, RISKCURVES helps in prioritising safety measures, optimising facility layouts, and ensuring that the overall risk remains within acceptable limits as defined by industry standards and regulations.

  • Support regulatory compliance

Advanced tools like FLACS, EFFECTS, and RISKCURVES are specifically designed to help meet regulatory requirements by providing the detailed analyses required for standards such as NFPA 59A and EN 1473. Their ability to produce reliable, validated results makes them invaluable in proving that a facility meets essential safety criteria.

  • Informed decision making

These advanced tools offer precise simulations and thorough risk assessments, giving decision-makers the clear data they need to choose the best site locations, facility layouts, and safety measures. This results in LNG facilities that are safer, more efficient, and cost-effective, with risks clearly identified and effectively controlled.

Modelling LNG pool spreading with FLACS CFD consequence analysis software
Figure 6. Modelling LNG pool spreading with FLACS.

While using advanced consequence and risk modelling tools in LNG siting offers clear benefits, there are also challenges that need to be managed to use them effectively. Understanding these challenges is important for achieving the best outcomes in facility design and safety.

Now, let’s look at the key challenges and considerations that accompany the use of these advanced tools

Challenges and considerations of using advanced modelling tools in LNG facility siting studies

Although modelling can provide more accurate and representative inputs into facility siting, there are several challenges that need to be addressed to ensure they are the right choice for your project. Here’s how these challenges can be managed:

  • Time-intensive processes:
    • Modelling studies require more time than simply applying prescriptive separation or exclusion distances from standard guidance. However, the additional time investment can result in more accurate and tailored separation distances or layouts.
    • By using accurate inputs, you may achieve less conservative and more efficient designs, ultimately leading to cost savings over time and enhanced safety.
  • Study complexity:
    • Risk-based studies, in particular, can become technically complex and challenging to conduct without prior experience.
    • To overcome this, consider involving experts with experience in modelling especially for facility siting applications. Their expertise can simplify the process and ensure that the study is both thorough and reliable, reducing the learning curve for your team.
  • Defining the process conditions:
    • At the early stages of a design, the process conditions may not be fully defined. A solution is to use preliminary data and assumptions that can be refined as the design progresses.
    • This approach allows for initial modelling to guide early design decisions, with flexibility to adjust as more detailed information becomes available.
  • Modelling the plant layout:
    • The plant design and layout might not be fully defined early on, but a base design is required to build a geometrical model for a CFD study.
    • A possibility to address this is by creating a flexible base design that can evolve as the project develops, ensuring that the modelling reflects the most current layout considerations.
  • Obtaining reliable data:
    • Accessing reliable data such as leak frequencies, meteorological conditions, terrain, and population data can be challenging for risk-based assessments.
    • You can start by using any existing site-specific data or historical reports available within your organisation or from previous studies. For meteorological and population data, there are publicly available databases such as those from national weather services or census data. These sources, while general, can provide a solid foundation for your assessment.
    • Furthermore, when data is limited, conducting sensitivity analyses within your modelling can help understand the impact of various assumptions. This approach allows you to identify the most critical data gaps and prioritise efforts to obtain the most impactful information.
Modelling LNG vapour cloud dispersion with FLACS CFD consequence analysis software
Figure 7. Modelling LNG vapour cloud dispersion with FLACS.

In summary, several factors need to be considered to determine the appropriateness of modelling in your siting studies. While advanced modelling presents some challenges, these can be effectively managed with the right approach and expertise. Ultimately, the type of study you choose will depend on your specific needs, the design stage, and the requirements set by relevant authorities.

Looking ahead

The latest edition of NFPA 59A includes updates for risk-based approaches to evaluating hazards, which are in line with international standards. These changes indicate that risk-based approaches and the corresponding modelling are becoming more common.

In conclusion, LNG facility siting involves understanding and applying a range of standards and guidelines to ensure the safety of facilities and the public. As the industry evolves, the shift towards risk-based approaches and the integration of modelling to support decisions are becoming more prevalent, offering more reliable methods for managing safety. By embracing these methods, the industry can achieve more reliable and informed decision-making, ultimately leading to safer and more efficient LNG facilities.

References

1. Barateiro, C.E., Gomez, J.S., and Soranz, R. (2013). LNG (Liquefied Natural Gas): The New Frontier in Metering Management. VII Rio Automation Congress, Rio de Janeiro, Brazil, 16-17 May 2013. Available at: Link 

2. Shell (2024). Global LNG demand to grow beyond 2040, driven by industrial demand in China and economic development in South Asia and South-east Asia. Available at: Link 

3. Oil Information Technology Journal (2012). Vapor dispersion modeler approved. Parallel solver JIP kicks-off. FlowViz postprocessor announced. Available at: Link 

Authors

Jake Connor

Jake Connor

Product Specialist at Gexcon

Related insights

Browse additional insights to deepen your understanding and stay informed on related topics.

Stay ahead in process safety and risk management

Get the latest trends in the field of process safety management straight to your inbox, and enhance your skills through knowledge sharing from industry experts.

Subsribe to our newsletter