The Dust / Powder Resistivity Test measures the electrical resistivity of dust or powders to evaluate the risk of electrostatic discharge, which can pose ignition hazards in powder handling systems.
Materials with resistivity above ~10¹⁰ Ω·m are prone to cone discharges, a serious ignition hazard if left uncontrolled.
This test is particularly relevant for processes involving bulk material handling, such as pneumatic transport, pouring, or decanting, where electrostatic charges can accumulate.
Why Dust / Powder Resistivity Test Matters?
The Dust / Powder Resistivity Test helps you identify if a material can build up static charge and cause ignition.
This is key for choosing the right grounding or inerting measures, reducing explosion risk during handling, and meeting safety standards like EN ISO/IEC 80079‑20‑2.
Contact usExamples of Powder Resistivity
| Material | Typical Resistivity (Ω·m) | Electrostatic Risk |
|---|---|---|
| Polyethylene (PE) | 1×10¹⁶–1×10¹⁷ | Very high – strong charge build-up risk |
| Nylon (Polyamide, PA) | 1×10¹³–1×10¹⁵ | High risk – may accumulate charge |
| Glass (as dust) | 1×10¹⁰–1×10¹⁴ | Moderate to high – cone discharge possible |
Testing Methodology
- The test is carried out in accordance with the European standard EN ISO/IEC 80079-20-2 “Explosive atmospheres – Part 20-2: Material Characteristics – Combustible dust test methods”, 2016
The Dust / Powder Resistivity Test, as outlined in EN ISO/IEC 80079‑20‑2:2016 (Section 8.4), measures the electrical resistivity of powders to assess their potential for electrostatic discharge. In this method, a dried powder sample is placed in an insulated test cell between two electrodes. A direct current voltage, typically between 100 and 1000 volts, is applied, and the resulting current is measured.
Using the known dimensions of the sample and electrodes, the bulk resistivity is calculated in ohm-metres (Ω·m). Powders with resistivity below 10¹⁰ Ω·m are generally not prone to cone discharges, while higher values indicate a greater risk. The test is performed under controlled temperature and humidity, as environmental conditions can influence results.

Value to Your Business
- Measuring volume resistivity helps you classify powders as conductive, dissipative, or insulative, and predict if they will build up static and pose a spark risk
- Identifying powders with resistivity over 10¹⁰ Ω·m helps you decide when grounding or inerting is needed to prevent dangerous electrostatic sparks
- Using resistivity data helps you choose conductive hoses, antistatic liners, and earthing systems that match your material’s needs
- Tailoring controls to actual resistivity helps you avoid overspecifying earthing or inerting measures and keeps safety efficient
- Providing resistivity results helps you meet EN ISO/IEC 80079‑20‑2 requirements and reassure regulators and insurers that electrostatic risks are addressed
- Understanding electrostatic behaviour helps you prevent ignition incidents that could shut down operations or harm staff
Featured Insights
Explore relevant materials providing insights into our service.
Validate your project with proven test data
Work with our specialists to get insights you need for smarter decisions.
Comprehensive combustible dust testing services
- Explosibility Screening Test (Yes/No) Read more
- Minimum Ignition Energy (MIE) of Dust Cloud Test Read more
- Minimum Ignition Temperature (MIT) of Dust Cloud Test Read more
- Minimum Ignition Temperature (MIT) of Dust Layer Test Read more
- Explosion Severity Test (Pmax, dP/dt, KST) Read more
- Lower Explosion Limit Test (LEL, MEC) Read more
- Limiting Oxygen Concentration (LOC) Test Read more
- Burning Behaviour Test Read more
- Dust / Powder Resistivity Test Read more
- Hot Storage Test in Wire Baskets (Self-Ignition Temperature) Read more
- Electrostatic Hazard Tests Read more
- UN Transportation Tests (UN Class 4) Read more